§ 14-90. Depiction of proposed physical layout.  


Latest version.
  • The following proposed features shall be shown on the sketch plat:

    (1)

    Title. The title under which the proposed subdivision is to be recorded, if known, with the name of the property owner(s) and designers and the date of the plat;

    (2)

    Street names. The name of all proposed streets.

    (3)

    Rights-of-way. Street rights-of-way and widths indicated, including any necessary right-of-way required for improvements as shown on the thoroughfare plan;

    (4)

    Sidewalks. All proposed sidewalk and bike lane locations;

    (5)

    Lots. Lot lines, lot numbers, block letters, and the total number of proposed lots within the development;

    (6)

    Dedications. Sites, if any, to be dedicated or reserved for common areas, public parks, open space, schools, playgrounds, multi-use trails, or other public uses, together with the purpose and the conditions or limitations of these dedications, if any;

    (7)

    Yards. Minimum building setback lines as required under the yard requirements of zoning ordinance;

    (8)

    Zoning conditions. All conditions of zoning and proposed deed restrictions shall be recited on the sketch plat;

    (9)

    Corner lots. Show that corner lots shall have an extra width of not less than fifteen (15) feet more than required for interior lots for the zoning district within which they are located;

    (10)

    Transitional buffers. Show transitional buffers, if any and any required screening fencing;

    (11)

    BMPs. Show conceptual location of storm water management and water quality BMP facilities on sketch plat;

    (12)

    IRF. Show proposed IRF contour, spot elevation (if available) and source;

    (13)

    Covenants. Indicate whether the proposed subdivision will be subject to private covenants and whether a homeowner's association will be established;

    (14)

    Sewer easements. Show a sanitary sewer easement with a minimum width of fifteen (15) feet for all county maintained lines not within county right-of-way;

    (15)

    Water main easements. Show a water main easement with a minimum width of fifteen (15) feet for all county maintained lines not within right-of-way;

    (16)

    Fire hydrants. Show new fire hydrant(s) and eight-inch fireline(s); and

    (17)

    Fencing. Show any required fencing around detention ponds, if required.

    (18)

    Electrical service. Show whether electrical service will be above ground or underground.